Tricab Marine Green Single Insulated 10mm² Tinned Copper Bonding Cable-Wire (SUR TRI T10GR)

  • Tricab
    • Tricab Marine Green Single Insulated 10mm² Tinned Copper Bonding Cable-Wire (SUR TRI T10GR)

    Tricab Marine Green Single Insulated 10mm² Tinned Copper Bonding Cable-Wire (SUR TRI T10GR)

    Marine Bonding Wire - Tinned Copper - 10mm² - For Electrically Connecting Metal Components to Anodes - Sold per metre
    • Online Price: $12.95 (including 10 % GST tax)


    - OR -

    Australia's Best Price on the Marine Bonding Wire - Tinned Copper - 10mm² (SUR TRI T10GR)

    Suits electrically bonding sacrificial anodes to the metal components of your boat that need protecting

    overview

    Marine Grade Green Tinned Copper Bonding Wire / Cable 10mm² (UP-XXXD/1C10 Green (SUR TRI T10G)

    Sold Per Meter

    NB: Cutting Charge Applies to per metre Lengths

    AS/NZS1125 approved Green Tinned Copper bonding Wire for electrically bonding sacrificial anodes to the metal components of your boat that need protecting. .  This is a top of the range bonding wire that more effectively conducts the low voltage currents found in the hull of boats.  Approved instead of black where the bonding system could be confused with other wires or fuel systems.
     
    An effective Vessel Bonding System relies on the quality of the bonding wire used.  MPS recommend high grade, multi strand, tinned copper earth wire as the minimum standard.
     
    Larger diameter, multiple strand- tinned copper wire  is more capable of carrying an extremely low voltage than a bare wire.    Tinned copper is also much more resistant to corrosion than standard copper and will help maintain the integrity of your bonding system and it's connections.
    It is possible for a bonding earth wire to conduct higher voltages by either accidental connection or during fault conditions.   Ensure that your bonding system is easily identifiable as an earth wire and properly insulated by only using green and yellow AS/NZS1125 approved wire.

    specification

    CONSTRUCTION
    Conductor: Finely stranded annealed copper
    to IEC 60228 Class 5&6 & AS/NZS 1125.

    Insulation:
    LSFLEX®R-30, Cross-linked,
    Polyolefinic, Thermoset, Flame Retardant,
    Low Smoke, Zero Halogen (HF-90 to
    IEC 60092-351) Splash resistant to oil, skydrol,
    petrol, acid, sea water. Resists ozone and UV.

    Sheath:
    LSFLEX®S-50, Polyolefinic,
    Flame Retardant, Low Smoke, Zero Halogen
    (SHF-1 to IEC 60092-359) Splash resistant to oil,
    skydrol, petrol, acid, sea water. Resists ozone
    and UV.

    OPERATING TEMP
    -40°C to +90°C

    VOLTAGE RATING
    600/1000 Volts

    SHEATH COLOUR
    Green

    STANDARDSAS/NZS 1125
    AS/NZS 1660.5.1
    AS/NZS 1660.5.2
    AS/NZS 1660.5.3
    AS/NZS 1660.5.6
    IEC 60228
    IEC 60092-350
    IEC 60092-353
    IEC 60332-1
    IEC 60332-3(A)
    IEC 60754-1&2
    IEC 61034-1&2

    APPROVALS
    LR, DNV, ABS, BV, GL, USCG